Tecnoil



SOLUTIONS

Oil booster for power generation plants

Oil pressurization from existing lubrication circuit, with ISO C5-M coating

Sector: Power Generation | Product: Oil booster

AISI piping

ISO coating standard

The project

Tecnoil designed and supplied an oil booster intended for the power generation sector. The unit draws oil from the plant's existing lubrication circuit and pressurizes it to feed other controls, integrating with the already installed hydraulic infrastructure.

Technical data sheet

Feature Detail
Application

Power generation — oil pressurization for controls

Architecture

Drawing from existing lubrication system

Pumps

Variable displacement piston pumps

Filtration

Double delivery filter

Hydraulic blocks

Aluminum

Piping

AISI 316L

Testing

Performed with flow rate report

Coating

ISO C5-M standard

Technical configuration

  1. Suction and pressurization architecture

The oil booster draws oil from the existing lubrication system to pressurize it for other plant controls.

  1. Variable displacement piston pumps

The unit is equipped with variable displacement piston pumps.

  1. Double delivery filtration

Double delivery filter to ensure the cleanliness of the pressurized oil sent to the controls.

  1. Materials for reliability

Aluminum hydraulic blocks and AISI 316L piping.

  1. Accumulation system

The unit integrates an accumulation system accompanying the pressurization circuit.

  1. Testing with flow rate report

The unit was tested, and a flow rate report was prepared, delivered with the supply.

  1. ISO C5-M coating

Coating cycle performed with thicknesses compliant with the ISO standard (C5-M).

Further information

Oil boosters and pressurization units

Power Generation Sector

Technical office and engineering quality

Discover

Do you have a similar project? Contact the technical office with your specification — we will propose a tailor-made solution.

Doppia centrale di lubrificazione per laminatoio

Double lubrication unit for rolling mill

Full redundancy with two 33,000-liter AISI 304 tanks

Centrali di potenza per forni EAF LF

Power units for EAF, LF furnaces

Four dedicated HPUs, AISI 316 and high-dynamic electrode regulation

Projects & Solutions