Tecnoil



SOLUTIONS

Hydraulic power unit for EAF furnace

165 kW, high-dynamic electrode regulation and dedicated accumulation

Sector: Steel Industry / Steelworks | Product: Power unit for EAF furnace

Installed power

Piston accumulators

Operating pressure

The project

Tecnoil designed and supplied the hydraulic power unit serving an EAF furnace. The configuration integrates the power required for the cycle, the high-dynamic regulation of the electrode bank, and an accumulation group sized based on the furnace users.

Technical data sheet

Feature Detail
Application EAF furnace
Installed power 165 kW
Motor configuration 3 motors (1 on standby)
Operating pressure 140 bar
Working flow rate 140 l/min
Electrode bank High-dynamic proportional valves NG16–NG35 (200–1,000 l/min)
Accumulation group 5 piston accumulators, 250 l each
Nitrogen reserve 30 cylinders, 75 l each (2,250 l total)

Technical configuration

  1. Motor-pump group with redundancy

Installed power of 165 kW distributed across three motors, one of which is on standby. Operating pressure of 140 bar, 140 liters in operation.

  1. Electrode and service bank with high-dynamic proportional valves

Bank dedicated to electrode movement and various services, equipped with high-dynamic proportional valves from NG16 to NG35, for flow rates between 200 and 1,000 l/min.

  1. Piston accumulation group

Accumulation group consisting of five 250-liter piston accumulators.

  1. Dedicated nitrogen reserve

On the nitrogen side of the accumulation group, 30 nitrogen cylinders of 75 liters each are installed, for a total capacity of 2,250 liters.

Further information

Hydraulic Power Units (HPU)

Discover

Steel and Iron Industry Sector

Discover

Technical office and engineering quality

Discover

Do you have a similar project? Contact the technical office with your specifications — we will propose a tailor-made solution.

Centrale oleodinamica per gru navale — anticorrosione C5 Very High

Hydraulic power unit for marine crane C5 Very High corrosion protection

165 kW, high-dynamic electrode regulation and dedicated accumulation

Centrali per colata continua

Power units for continuous casting machines

Soft reduction, Performance Level D safety, and future line expandability

Projects & Solutions