Hydraulic power unit for EAF furnace
165 kW, high-dynamic electrode regulation and dedicated accumulation
Sector: Steel Industry / Steelworks | Product: Power unit for EAF furnace
Installed power
Piston accumulators
Operating pressure
The project
Tecnoil designed and supplied the hydraulic power unit serving an EAF furnace. The configuration integrates the power required for the cycle, the high-dynamic regulation of the electrode bank, and an accumulation group sized based on the furnace users.
Technical data sheet
| Feature | Detail |
|---|---|
| Application | EAF furnace |
| Installed power | 165 kW |
| Motor configuration | 3 motors (1 on standby) |
| Operating pressure | 140 bar |
| Working flow rate | 140 l/min |
| Electrode bank | High-dynamic proportional valves NG16–NG35 (200–1,000 l/min) |
| Accumulation group | 5 piston accumulators, 250 l each |
| Nitrogen reserve | 30 cylinders, 75 l each (2,250 l total) |
Technical configuration
- Motor-pump group with redundancy
Installed power of 165 kW distributed across three motors, one of which is on standby. Operating pressure of 140 bar, 140 liters in operation.
- Electrode and service bank with high-dynamic proportional valves
Bank dedicated to electrode movement and various services, equipped with high-dynamic proportional valves from NG16 to NG35, for flow rates between 200 and 1,000 l/min.
- Piston accumulation group
Accumulation group consisting of five 250-liter piston accumulators.
- Dedicated nitrogen reserve
On the nitrogen side of the accumulation group, 30 nitrogen cylinders of 75 liters each are installed, for a total capacity of 2,250 liters.
Further information
Hydraulic Power Units (HPU)
Discover
Steel and Iron Industry Sector
Discover
Technical office and engineering quality
Discover
Do you have a similar project? Contact the technical office with your specifications — we will propose a tailor-made solution.

Hydraulic power unit for marine crane C5 Very High corrosion protection
165 kW, high-dynamic electrode regulation and dedicated accumulation

Power units for continuous casting machines
Soft reduction, Performance Level D safety, and future line expandability